Main lug load center designed for service entrance equipment. Main lugs only. Single-phase 3-wire flush or surface mount. Solid neutral bar and cover included. Optional ground bar kits must be...
Main lug load center designed for service entrance equipment. Main lugs only. Single-phase 3-wire flush or surface mount. Solid neutral bar and cover included. Optional ground bar kits must be ordered separately. Load centers that accept BD and BQ type circuit breakers have a notched bus bar. UL (Underwriter's Laboratories) listed. No. BR24L70FP: Series: BR Amperage: 70 Number Of Spaces: 2 Max Number of Poles: 4 Voltage: 120/240 Enclosure Type: Indoor Mount Type: Flush Phase: Single Wire Size:...
Eaton BR Outdoor Plug On Neutral Main Lug Load Center
Eaton BR Outoor Main Lug Load Center
Eaton BR Plug On Neutral GFCI Breaker
Eaton BR Plug On Neutral Outdoor Main Lug Load Center
Single-phase plug-on neutral main circuit breaker load center. Suitable for indoor use only. Includes NEMA (National Electrical Manufacturers Association) Type 3R cover. No. BRP10B100: Series: BR...
Single-phase plug-on neutral main circuit breaker load center. Suitable for indoor use only. Includes NEMA (National Electrical Manufacturers Association) Type 3R cover. No. BRP10B100: Series: BR Amperage: 100 Number Of Spaces: 10 Max Number of Circuits: 20 Voltage: 120/240 Enclosure Type: Indoor Mount Type: Bolt On Phase: Single Wire Size: #4 AWG to 1/0 2 Certification: UL Listed Pkg Qty: 1 Package Type: Box No. BRP12B100: Series: BR Amperage: 100 Number Of Spaces: 12 Max Number of Circuits:...
Plug-on neutral load center value pack. Features quick and easy installation along with a clean and professional look. Plug-on neutral breaker box eliminates pigtail connection. Dedicated neutral...
Plug-on neutral load center value pack. Features quick and easy installation along with a clean and professional look. Plug-on neutral breaker box eliminates pigtail connection. Dedicated neutral bus for breaker connection. In-board neutral bar increases gutter space for professional installation of conductors. Backed out neutral screws for quick connection of neutral and ground conductors. Optimized knockout locations for additional access and easy removal. Self-leveling tabs allow for quick...
Single-phase 3-wire plug-on neutral main lug load center. Suitable for indoor use only. Includes NEMA (National Electrical Manufacturers Association) Type 3R cover. No. BRP12L125: Series: BR...
Single-phase 3-wire plug-on neutral main lug load center. Suitable for indoor use only. Includes NEMA (National Electrical Manufacturers Association) Type 3R cover. No. BRP12L125: Series: BR Amperage: 125 Number Of Spaces: 12 Max Number of Poles: 24 Voltage: 120/240 Enclosure Type: Indoor Mount Type: Bolt On Phase: Single Wire Size: #6 to 2/0 Height (In.): 36.5 Width (In.): 16 Depth (In.): 4.5 Certification: UL Listed Pkg Qty: 1 Package Type: Box
Eaton single-pole plug-on GFCI (ground fault circuit interrupter) breaker. Features a 10 kAIC (kilo amperes interrupting capacity) rating. Ideal for use in areas where shocks occur more often such...
Eaton single-pole plug-on GFCI (ground fault circuit interrupter) breaker. Features a 10 kAIC (kilo amperes interrupting capacity) rating. Ideal for use in areas where shocks occur more often such as kitchens bathroom and workshops. Breaks the circuit when electrical leakage is detected. No. BRN115GF: Amperage: 15 Number of Poles: 1 Interruption Type: GFCI Voltage: 120/240 Frame Size: 1-Space Width (In.): 1 Mount Type: Plug-On Wire Size: #14-4 AWG Certification: UL Listed Pkg Qty: 1 Package...
Eaton BR Service Entrance Equipment Main Lug Load Center
Dual purpose arc fault/ground fault circuit breaker. Plug-on single pole 10 kAIC. LED diagnostics included. Short body design. No. BRN115DF: Amperage: 15 Number of Poles: 1 Interruption Type:...
Dual purpose arc fault/ground fault circuit breaker. Plug-on single pole 10 kAIC. LED diagnostics included. Short body design. No. BRN115DF: Amperage: 15 Number of Poles: 1 Interruption Type: CAFCI/GFCI Voltage: 120 Frame Size: 1-Space Width (In.): 1 Mount Type: Plug-In Wire Size: #14-4 AWG Certification: UL Listed Pkg Qty: 1 Package Type: Box No. BRN120DF: Amperage: 20 Number of Poles: 1 Interruption Type: CAFCI/GFCI Voltage: 120 Frame Size: 1-Space Width (In.): 1 Mount Type: Plug-In Wire...
BR style spa panel. 50-amp self-test 2 pole electrical disconnect with GFCI (ground fault circuit interrupter) protection. For use with hot tubs and spas. 240-volt. Includes (1) 50-amp GFCI circuit...
BR style spa panel. 50-amp self-test 2 pole electrical disconnect with GFCI (ground fault circuit interrupter) protection. For use with hot tubs and spas. 240-volt. Includes (1) 50-amp GFCI circuit breaker. UL (Underwriter's Laboratories) listed. No. BR50SPAST: Amperage: 50 Number of Poles: 2 Indoor/Outdoor: Outdoor Voltage: 240 Certification: UL Listed Pkg Qty: 1 Package Type: Shrink Wrap
Type BW main breaker. Ideal for use with Cutler Hammer brand type BR load centers. Includes: Main breaker mounting screw 2 bus torque nuts and instructions. 2-pole 120 volt/240 volt 10 000 kAIC...
Type BW main breaker. Ideal for use with Cutler Hammer brand type BR load centers. Includes: Main breaker mounting screw 2 bus torque nuts and instructions. 2-pole 120 volt/240 volt 10 000 kAIC (amps interrupting capacity). UL (Underwriter's Laboratories) listed. No. BW2200: Amperage: 200 Number of Poles: 2 Interruption Type: Standard Trip Voltage: 120/240 Frame Size: 2-Space Width (In.): 5.25 Height (In.): 5 Depth (In.): 6.25 Mount Type: Bolt-On Wire Size: #2 AWG to 300 KCMIL Certification:...
Circuit breaker for use in CH load centers. 120 volt/240 volt 10 000 AIC (amps interrupting capacity). UL (Underwriter's Laboratories) listed. No. CH260CS: Amperage: 60 Number of Poles: 2...
Circuit breaker for use in CH load centers. 120 volt/240 volt 10 000 AIC (amps interrupting capacity). UL (Underwriter's Laboratories) listed. No. CH260CS: Amperage: 60 Number of Poles: 2 Interruption Type: Standard Trip Voltage: 120/240 Frame Size: 2-Space Width (In.): 1.5 Mount Type: Plug-In Wire Size: #14-2 AWG Certification: UL Listed Pkg Qty: 1 Package Type: Clamshell No. CH260: Amperage: 60 Number of Poles: 2 Interruption Type: Standard Trip Voltage: 120/240 Frame Size: 2-Space Width...