100-amp main breaker plug-on neutral-ready load center value pack featuring Qwik-Grip wire management system to speed up wire installation. Eliminates the need for almost all knock-outs making...
100-amp main breaker plug-on neutral-ready load center value pack featuring Qwik-Grip wire management system to speed up wire installation. Eliminates the need for almost all knock-outs making rough-ins easy and fast. Also reduces the risk of mistakes and having to install connectors because wires slide right into the Qwik-Grip insert in seconds. Also makes adding a circuit simple. No pigtail wires for easy installation and fewer number of wires to deal with. Ideal for remodels or service...
Homeline GFCI (ground fault circuit interrupter) breaker. Helps protect against dangerous electrical shock. Single-pole 1 space required. Compatible with Homeline load centers and CSED devices. ANSI...
Homeline GFCI (ground fault circuit interrupter) breaker. Helps protect against dangerous electrical shock. Single-pole 1 space required. Compatible with Homeline load centers and CSED devices. ANSI (American National Standards Institute) certified and UL (Underwriter's Laboratories) listed. Rated for 120 volts and 10 000 AIR. No. HOM120GFICP: Amperage: 20 Number of Poles: 1 Interruption Type: GFCI Voltage: 120 Frame Size: 1-Space Width (In.): 2 Mount Type: Plug-In Wire Size: #14-8 AWG...
Homeline tandem circuit breaker. 2 single-poles requiring 1 space. Used for overload and short-circuit protection of electrical systems. Compatible with Homeline load centers and CSED devices. Rated...
Homeline tandem circuit breaker. 2 single-poles requiring 1 space. Used for overload and short-circuit protection of electrical systems. Compatible with Homeline load centers and CSED devices. Rated for 120 volt/240 volt and 10 000 AIR. Designed exclusively for the residential market. ANSI (American National Standards Institute) certified and UL (Underwriter's Laboratories) listed. No. HOMT1515CP: Amperage: 15/15 Number of Poles: Twin Interruption Type: Standard Trip Voltage: 120/240 Frame...
Square D Homeline 2-space 4-circuit spa pack load center. Protects single pole and double pole loads against ground and overcurrent faults. Provides protection for outdoor circuits such as hot tubs...
Square D Homeline 2-space 4-circuit spa pack load center. Protects single pole and double pole loads against ground and overcurrent faults. Provides protection for outdoor circuits such as hot tubs fountains swimming pools or spas. Engineered for fast installation and wire savings. Includes (1) 50 amp Homeline outdoor metallic load center with an installed HOM250GFI. No. HOME250SPA: Series: Homeline Amperage: 50 Number Of Spaces: 2 Max Number of Circuits: 2 Voltage: 120/240 Enclosure Type:...
Homeline Value Pack offers a value mix of products for a load center project. Plug-on Neutral ready and built with plated aluminum bus bar that is tested and listed only for Homeline circuit...
Homeline Value Pack offers a value mix of products for a load center project. Plug-on Neutral ready and built with plated aluminum bus bar that is tested and listed only for Homeline circuit breakers. 200 amp main breaker included. Engineered for fast installation and wire savings. Includes (3) 20 amp single-pole (HOM120) circuit breakers and (2) 30 amp double-pole (HOM230) circuit breakers. Cover included. UL (Underwriter's Laboratories) listed for residential and commercial power...
Square D Load Center Replacement Cover Screws
Type QO load center with cover and main breaker installed. Ideal for outdoor power distribution. Plug-on Neutral ready and features a copper bus bar that is plated for reliability. 100 amp main...
Type QO load center with cover and main breaker installed. Ideal for outdoor power distribution. Plug-on Neutral ready and features a copper bus bar that is plated for reliability. 100 amp main breaker included. Offers a protective rainproof cover to safeguard the internal contents of the NEMA Type-3R enclosure from water exposure. Single-phase 3-wire. Shielded copper bus bar 3 ground bar locations. QO load centers are tested and listed only for QO circuit breakers. Engineered for fast...
Square D QO 2-Pole GFCI Breaker
Non-fused 60A air conditioner disconnect for residential and commercial use enclosed molded case switch (does not provide overcurrent protection). 2-wire rainproof maximum 10 HP rating. 60A/240V. UL...
Non-fused 60A air conditioner disconnect for residential and commercial use enclosed molded case switch (does not provide overcurrent protection). 2-wire rainproof maximum 10 HP rating. 60A/240V. UL (Underwriter's Laboratories) listed. No. QO200TRCP: Amperage: 60 Voltage: 240 NEMA Configuration: 3R Series: QO Horsepower: 10 Wire Size: #14 Depth (In.): 3.9 Certification: UL Listed Pkg Qty: 1 Package Type: Shrink Wrap
Fills opening in QO load center covers when twist-out has been removed. Use only in QO load centers filling the spaces where no circuit is attached. UL (Underwriter's Laboratories) listed and ANSI...
Fills opening in QO load center covers when twist-out has been removed. Use only in QO load centers filling the spaces where no circuit is attached. UL (Underwriter's Laboratories) listed and ANSI (American National Standards Institute) certified. No. QOFPCP: Width (In.): 0.75 Series: QO Load Center Pkg Qty: 3 Package Type: Card
Dual function circuit breaker. Features space and labor savings. Engineered to meet NEC (National Electrical Code) requirements. Combines two critical technologies - combination arc fault protection...
Dual function circuit breaker. Features space and labor savings. Engineered to meet NEC (National Electrical Code) requirements. Combines two critical technologies - combination arc fault protection and ground fault protection in one easy to install device. Integrated with time saver diagnostics a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button. Compatible with QO load centers only. 120 volt 10 000 AIR. ANSI (American Nation...
QO circuit breaker for use in QO load centers. Intended for overload and short-circuit protection of electrical systems. ANSI (American National Standards Institute) certified and UL (Underwriter's...
QO circuit breaker for use in QO load centers. Intended for overload and short-circuit protection of electrical systems. ANSI (American National Standards Institute) certified and UL (Underwriter's Laboratories) listed. Rated for 120 volt/240 volt and 10 000 AIR. Features the exclusive Visi-Trip indicator. When the circuit breaker trips the handle snaps to a midpoint and a highly visible red indicator easily identifies the tripped breaker. No. QO115CP: Amperage: 15 Number of Poles: 1...